IONIZATION TEST KITS SELECTION GUIDE                                                                                      STATIC DECAY







                                                                                                                                                                    PDT-740B STATIC DECAY TIMER


                                                                                                                                                                    MEASURE DECAY TIMES FOR IONIZERS AND MATERIALS

                                                                                                                                                                    • Designed to measure the time required for a 1,000 volt charge
                                                                                                                                                                     to dissipate to less than 100, 50 or 10 volts in tenths of a second
                                                                                                                                                                    • Used to evaluate the static decay capabilities of materials, personnel,
                                                                                                                                                                     equipment and other products                                                    IONIZATION TEST KITS
                                                                                                                                                                    • Compatible with most portable charge plate monitors and field meters
                                                                                                                                                                     having an analog output of ±2 volts
                                                                                                                                                                    • Used with the PFM-711A or PFM-711B Field Meters
                                                                                                                                                                    • Can be used with the PGB-745 Decay Electrodes or PRF-911 Concentric Ring




                                                   PFK-105                  PFK-101                   PIK-110
                                              Ionization Test Kit         Basic Field Kit          Ionization Kit


                Measure Electrostatic Fields               √                        √                        √                                                      PGB-745 DECAY ACCESSORY SET


                Analyze and Balance Ionizers               √                        √                        √
                                                                                                                                                                    MEASURE CHARGE MOVEMENT AND DECAY TIME ACROSS MATERIALS
                   Measure Decay Times                     √                        √                        √                                                      • Designed for measuring charge movement and decay time

                 Measure Temperature and               ---                          √                        √                                                       of ESD controlled materials
                        Humidity                                                                                                                                    • The set consists of two stainless steel electrodes and two
                                                                                                                                                                     very high resistance test leads selected for this application
                  Measure Air Flow Speed               ---                      ---                          √                                                      • The high resistance leads minimize leakage during the test cycle
                                                                                                                                                                     and are equipped with male banana plugs
              Includes Grounding Accessories           ---                          √                        √

                   Meets ANSI/ESD S3.1                     √                        √                        √

                  Meets ANSI/ESD SP3.3                     √                        √                        √





























      30                                                                                                                                                                                                                                             31