Page 275 - Wiha catalogue 2022
P. 275
Installation pliers TriCut Professional electric Installation pliers TriCut Classic
Z 14 1 06 Z 14 1 01
Order-No. Order-No.
38552 170 7“ 13 1.6 - 5 38627 170 7 13 1.6 - 5
38853 170 7“ 13 1.6 x 5 38854 170 7“ 13 1.6 x 5
Manufactured acc. to IEC 60900.
INFOBOX:
VDE-certified tools
Wiha VDE-tested tools are subject to stringent safety test procedures.
All tools with the special marking have been tested at 10,000 V AC and are therefore approved for use at 1,000 V AC and 1,500 V DC.
The following equipment is required for all work on or around live components and should be appropriate for the specific task
• insulating personal protective equipment
• insulating safety mechanisms
• insulated tools
Before starting work, you must disconnect all active, live components of electrical machines and equipment and ensure that they remain
disconnected while you carry out the work.
This is achieved by complying with the five safety rules:
• disconnect
• secure against reconnection
• ensure power is switched off
• earth and short-circuit
• cover or block off adjacent live components
Certified by the VDE Testing and Certification Institute and individually tested according to the international standard IEC 60900.
275