Page 164 - Wiha catalogue 2022
P. 164

Torque screwdriver set TorqueVario -S electric
                                        ®




















                                                                                                SLIM
                                                                                                TECHNOLOGY

              0,8-5,0 Nm mixed, variably adjustable torque limit, 19 pcs. incl. folding bag                   2872T18
              Order-No.
              36791                                                                                       1
                      1 x Torque screwdriver TorqueVario -S electric variably adjustable torque limit
                                               ®
                      1 x Setting tool for torque screwdriver with long handle
                      1 x Adapter TorqueVario-S electric for slimBits
                      1 x 2.5 mm / 1 x 3.5 mm / 1 x 5.5 mm / 1 x 6.5 mm
                      1 x PH1 / 1 x PH2
                      1 x PZ1 / 1 x PZ2
                      1 x SL/PZ1 / 1 x SL/PZ2
                      1 x T9 / 1 x T10 / 1 x T15 / 1 x T20 / 1 x T25
                      1 x Folding bag
              DIN EN ISO 6789.
              Manufactured acc. to IEC 60900.





                 INFOBOX:
                 VDE-certified tools



                 Wiha VDE-tested tools are subject to stringent safety test procedures.
                 All tools with the special marking have been tested at 10,000 V AC and are therefore approved for use at 1,000 V AC and 1,500 V DC.
                 The following equipment is required for all work on or around live components and should be appropriate for the specific task
                 •   insulating personal protective equipment
                 •   insulating safety mechanisms
                 •   insulated tools

                 Before starting work, you must disconnect all active, live components of electrical machines and equipment and ensure that they remain
                 disconnected while you carry out the work.
                 This is achieved by complying with the five safety rules:
                 •   disconnect
                 •   secure against reconnection
                 •   ensure power is switched off
                 •   earth and short-circuit
                 •   cover or block off adjacent live components
                 Certified by the VDE Testing and Certification Institute and individually tested according to the international standard IEC 60900.






              164
   159   160   161   162   163   164   165   166   167   168   169